![apc powerchute software download apc powerchute software download](https://images-na.ssl-images-amazon.com/images/I/51KvY1FeOnL._SX425_.jpg)
$ udevadm info -attribute-walk -name=/dev/usb/hiddev0 | egrep 'manufacturer|product|serial'ĪTTRS.
Apc powerchute software download serial number#
The manufacturer and serial number attributes will be used by udev to uniquely identify each UPS on the system.
Apc powerchute software download serial numbers#
Each UPS performs different actions for different events.Ĭonnect each UPS and determine they are visible USB devicesīus 004 Device 002: ID 051d:0002 American Power Conversion Uninterruptible Power Supplyīus 008 Device 003: ID 051d:0002 American Power Conversion Uninterruptible Power Supplyĭetermine the serial numbers for each UPS
![apc powerchute software download apc powerchute software download](https://evever.weebly.com/uploads/1/2/4/8/124855792/251881223.jpg)
One UPS is named "UPS Network" and controls power to networking equipment, and the other UPS is named "UPS Server" and controls power to the computer monitoring both UPSes. The UPS devices used as examples below are two APC SmartUPS SUA1500 devices connected to one computer via USB. In order to control multiple UPS devices, extra steps must be taken that are not required for monitoring only one UPS.įor multiple UPS monitoring to work, each UPS must be uniquely identifiable and uniquely named on the monitoring computer, separate nf files must be used for each UPS device, and a modified apcupsd init.d script must be used to control multiple apcupsd daemon processes. The following configuration steps can be used for monitoring one or more UPS devices from one computer. The log file /var/log/apcupsd.events says if the daemon has started correctly. Now you can start the daemon with the command: UPSTYPE : the type of UPS you have (USB, RS232,…)Īnd in /etc/default/apcupsd, you indicate that the configuration is done (not needed with systemd). UPSCABLE : the type of cable connecting the UPS to your computer. In /etc/apcupsd/nf, you must specify the type of UPS: The daemon controls and monitors the status of UPS and allows your computer to run for a specified length of time on UPS power, and then executes a controlled shutdown in the case of an extended power failure.īefore starting the daemon, you must at minimum configure /etc/apcupsd/nf and /etc/default/apcupsd.
![apc powerchute software download apc powerchute software download](https://img.netzwelt.de/dw320_dh180_sw0_sh0_sx0_sy0_sr16x9_nu0/software/2011/screenshots/15004/logitech-mouseware-316x283.jpg)
To see if your ups is recognized, use the command:īus 001 Device 002: ID 051d:0002 American Power Conversion Back-UPS Pro 500/1000/1500 The documentation is available in the apcupsd-doc package.